3
ATTENTION:
• Always use a power supply provided by or specied by Extron. Use
of an unauthorized power supply voids all regulatory compliance
certication and may cause damage to the supply and the end
product.
• Unless otherwise stated, the AC/DC adapters are not suitable for
use in air handling spaces or in wall cavities. The power supply is
to be located within the same vicinity as the Extron AV processing
equipment in an ordinary location, Pollution Degree 2, secured to the
equipment rack within the dedicated closet, podium, or desk.
• The installation must always be in accordance with the applicable
provisions of National Electrical Code ANSI/NFPA 70, article 75 and
the Canadian Electrical Code part 1, section 16. The power supply
shall not be permanently xed to building structure or similar structure.
Connect Power
Connect the provided 12VDC power supply to the rear panel captive screw connector (see gure 1,
a
). and plug the AC power
cord into 100-240 VAC, at 50-60 Hz.
DC Power Cord
Captive Screw
Connector
AC Power Cord
External
Power Suppl
(12 VDC, 1 A
Ground
+12 VDC
3/16"
(5 mm) Max.
Figure 5. Power Supply Wiring
Configuring the MPS601
The MPS601 can be congured using a connected PC and the Extron Product Conguration Software or using SIS commands.
To congure the MPS601 using the Product Conguration Software, install the software (available on the Extron website,
www.extron.com) on a PC connected to the MPS601 by the rear panel remote (RS-232) port (see gure 1,
h
), or front panel
USB Cong port (see gure 6,
b
). After the installation, start the program. See the MPS601 User Guide and the Product
Configuration Software Help File for additional information.
To congure the MPS601 using SIS commands, see the MPS601 User Guide.
MPS 601
MEDIA PRESENTATION SWITCHER
CONFIG
SIGNAL
INPUTS
INPUTS
OUTPUT
12 3 45 6
HDCP
1 2 3 4 5 6
AUTO
SWITCH
ab fc d e
Figure 6. MPS601 Front Panel
Setup and Operation
a Power on all connected devices, then apply power to the MPS601. The Auto Switch LED lights when auto-input switching is
active.
b One mini type-B female USB Cong port connects to a host computer for conguring the switcher and upgrading rmware.
c Input switching. The input group has six buttons with associated green LEDs. Press an input button to switch the input to the
HDMI output. The associated LED lights. Only one of the six inputs can be selected at a time.
d Input signal LEDs. Six green LEDs indicate:
• The LEDs for RGBHV inputs 1 and 2 light when horizontal sync is detected on the input.
• The LEDs for HDMI inputs 3 to 6 light when TMDS clock activity is detected on the input.
NOTE: If a connected HDMI source is HDCP encrypted, the associated input signal LED does not light until HDCP is
authenticated.