Extron electronics MEDIALINK MLC 52 Instrukcje Operacyjne

Przeglądaj online lub pobierz Instrukcje Operacyjne dla Projektory danych Extron electronics MEDIALINK MLC 52. Extron electronics MEDIALINK MLC 52 Operating instructions Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 124
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów

Podsumowanie treści

Strona 1 - MLC 52 Series

MLC 52 SeriesMediaLink™ Controllers68-1079-01 Rev. D04 07

Strona 2 - Precautions

Introduction, cont’dMLC 52 Series MediaLink Controllers • Introduction1-4MLC 52 Application ExamplesExtron MLC 52 Basic MediaLink Controller MLC 52 DI

Strona 3 - Table of Contents

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-40Programming the MLC 52 for control by the IR 452 RemoteThe o

Strona 4 - Table of Contents, cont’d

5-41MLC 52 Series MediaLink Controllers • Serial Communication IR learning readiness prompt5. When you are ready to start, click OK. The tex

Strona 5

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-42If the command is learned successfully, the Current Button f

Strona 6

5-43MLC 52 Series MediaLink Controllers • Serial CommunicationPlaying an IR commandUsing emulation modeThe MLC 52 configuration program features an em

Strona 7 - Chapter One

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-443. You can create a new configuration starting from the defa

Strona 8 - Introduction

5-45MLC 52 Series MediaLink Controllers • Serial Communicationc. Double-click on the configuration file that you want to use inemulation mode. Its na

Strona 9 - Options and accessories

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-46Click the button for the MLC type that you want to configure

Strona 10 - Introduction, cont’d

5-47MLC 52 Series MediaLink Controllers • Serial CommunicationInitial configuration options screenResettingUsing the configuration software, you can r

Strona 11 - Chapter Two

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-48• Click Yes if you want to save the current configuration.

Strona 12 - Installation

5-49MLC 52 Series MediaLink Controllers • Serial Communication8. On the Save As window that opens, browse to the folder on your computerwhere you want

Strona 13 - Installation Procedures

MLC 52 Series2Chapter TwoInstallationInstallation OverviewUL RequirementsInstallation Procedures

Strona 14 - Installation, cont’d

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-504. Locate and select the new firmware file. Firmware files

Strona 15 - Replacing button labels

5-51MLC 52 Series MediaLink Controllers • Serial CommunicationUsing Simple Instruction Set (SIS™) CommandsSimple Instruction set (SIS) commands can be

Strona 16

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-52Symbol definitions= CR/LF (carriage return/line feed) (hex 0

Strona 17

5-53MLC 52 Series MediaLink Controllers • Serial CommunicationCommand/response table for SIS commandsCommand ASCII Command Hexadecimal Unit response A

Strona 18

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-54Command/response table for advanced instructions (for the ML

Strona 19

MLC 52 SeriesAAppendix ASpecifications, Part Numbers, and AccessoriesSpecificationsPart Numbers and Accessories

Strona 20

MLC 52 Series MediaLink Controllers • Specifications, Part Numbers, and AccessoriesA-2Specifications, Part Numbers, and AccessoriesSpecificationsContr

Strona 21 - Wiring for IR control

A-3MLC 52 Series MediaLink Controllers • Specifications, Part Numbers, and AccessoriesProduct weightMLC 52 RS, MLC 52 IR ... 0.2 lb (0.1 kg)MLC 52 RS

Strona 22

Specifications, Part Numbers, and Accessories, cont’dMLC 52 Series MediaLink Controllers • Specifications, Part Numbers, and AccessoriesA-4Optional ac

Strona 23 - IR 452 Remote

MLC 52 SeriesBAppendix BTemplatesMLC 52 IR and MLC 52 RS TemplateMLC 52 IR VC and MLC 52 RS VC Template

Strona 24

MLC 52 Series MediaLink Controllers • Installation2-2InstallationInstallation OverviewCAUTIONInstallation and service must be performed by authorized

Strona 25 - Wiring the VC port

MLC 52 Series MediaLink Controllers • TemplatesB-2TemplatesUse the rough-in templates in this appendix as guides to measure and mark thehole in the wa

Strona 26

B-3MLC 52 Series MediaLink Controllers • TemplatesMLC 52 IR VC and MLC 52 RS VC TemplateMLC 52 VC(Front View)Cut-Out Template for Extron's 4.60&q

Strona 27 - Wall Mounting Bracket

Templates, cont’dMLC 52 Series MediaLink Controllers • TemplatesB-4

Strona 28

FCC Class A NoticeNote: This equipment has been tested and found to comply with the limits for a Class A digitaldevice, pursuant to part 15 of the FC

Strona 29 - Chapter Three

© 2007 Extron Electronics. All rights reserved.Extron Electronics, USA1230 South Lewis StreetAnaheim, CA 92805800.633.9876 714.491.1500 FAX 714.

Strona 30 - Operation

2-3MLC 52 Series MediaLink Controllers • InstallationUL RequirementsThe Underwriters Laboratories (UL) requirements listed below pertain to theinstall

Strona 31 - MLC 52 IR and RS

Installation, cont’dMLC 52 Series MediaLink Controllers • Installation2-4To prepare the site,1. Choose a location that will allow cable runs without i

Strona 32 - Operation, cont’d

2-5MLC 52 Series MediaLink Controllers • Installation FaceplateStandoffMLC 52Installing the MLC onto a new faceplate (bottom view)Replacing b

Strona 33 - Receiving MLC

Installation, cont’dMLC 52 Series MediaLink Controllers • Installation2-64. Lift out the transparent square label that you want to replace, being care

Strona 34

2-7MLC 52 Series MediaLink Controllers • Installation Wall opening flush with edge of box Installation Cable Cable Clamp Screws or Nails Wall S

Strona 35 - > VCR

Installation, cont’dMLC 52 Series MediaLink Controllers • Installation2-8Rear panel and cable connectionsThe following diagrams show the locations of

Strona 36

2-9MLC 52 Series MediaLink Controllers • Installation1IR learner/transmitter — These sensors allow for IR control of the MLC andfor IR learning. The

Strona 37 - Setting up button macros

PrecautionsThis symbol is intended to alert the user of important operating and maintenance(servicing) instructions in the literature provided with th

Strona 38

Installation, cont’dMLC 52 Series MediaLink Controllers • Installation2-10Wiring the control connectorThe display and source control connector allows

Strona 39 - Amplifiers

2-11MLC 52 Series MediaLink Controllers • InstallationWiring for IR controlIf you intend to control display and/or input devices via infrared (IR) com

Strona 40

Installation, cont’dMLC 52 Series MediaLink Controllers • Installation2-12Wiring for RS-232 control (RS models only)The MLC 52 RS and the MLC 52 RS VC

Strona 41 - Selecting Inputs

2-13MLC 52 Series MediaLink Controllers • Installation3. Attach a 3.5 mm, 5-pole captive screw connector to one end of the cable and a6-pole captive s

Strona 42

Installation, cont’dMLC 52 Series MediaLink Controllers • Installation2-14Wiring an IRL 20The Extron IRL 20 is a hardwired IR signal receiver that can

Strona 43

2-15MLC 52 Series MediaLink Controllers • InstallationWiring the power connectorThe control connector also contains a power connector for the MLC 52.

Strona 44

Installation, cont’dMLC 52 Series MediaLink Controllers • Installation2-16Mounting the MLC 52Once the system has been cabled, configured, and tested,

Strona 45 - Chapter Four

2-17MLC 52 Series MediaLink Controllers • InstallationWall MLC 52 DISPLAYOFF ON VIDEO VOL VOL PC Extron Wall Mounting Bracket MLC 52 Mounting the MLC

Strona 46 - Special Applications

Installation, cont’dMLC 52 Series MediaLink Controllers • Installation2-18

Strona 47 - COMPUTER

MLC 52 Series3Chapter ThreeOperationDisplay Device ControlFront Panel Features and OperationConfiguring the MLC 52 Using IRUsing the MLC 52 VC Models

Strona 48 - Special Applications, cont’d

iMLC 52 Series MediaLink Controllers • Table of ContentsTable of ContentsChapter 1 • Introduction ...

Strona 49 - Projector Remote Type A

MLC 52 Series MediaLink Controllers • Operation3-2OperationDisplay Device ControlThe MLC 52 IR models can control a projector or other display device

Strona 50

3-3MLC 52 Series MediaLink Controllers • Operation• Input mode: Buttons in this mode are grouped together so that only one ofthem can be active at a

Strona 51 - Confirmation

Operation, cont’dMLC 52 Series MediaLink Controllers • Operation3-42Input selection buttons — These buttons are preprogrammed to select inputsources.

Strona 52

3-5MLC 52 Series MediaLink Controllers • OperationConfiguring the MLC 52 Using IRThe MLC 52 can be programmed/configured via IR by the following metho

Strona 53 - Multi-coded IR Functionality

Operation, cont’dMLC 52 Series MediaLink Controllers • Operation3-6 11234EON234TxIR OUTGNDIR INGND+ 12V11234EON234TxIR OUTGNDIR INGND+ 12VLess Tha

Strona 54

3-7MLC 52 Series MediaLink Controllers • OperationAfter approximately 17% of the data has been transferred, the On buttonlights and remains lit to max

Strona 55

Operation, cont’dMLC 52 Series MediaLink Controllers • Operation3-83. Press the button on the MLC that will store the IR code that you want theMLC to

Strona 56

3-9MLC 52 Series MediaLink Controllers • Operation7. Press the buttons that you configured to verify that the commands youentered have been learned.

Strona 57

Operation, cont’dMLC 52 Series MediaLink Controllers • Operation3-10Configuring a single button for input source selectionIf you want to use only one

Strona 58

3-11MLC 52 Series MediaLink Controllers • OperationUsing the MLC 52 VC Models with the MPA Series PowerAmplifiersThe dedicated volume control knob on

Strona 59 - Projector Remote Type B

ii MLC 52 Series MediaLink Controllers • Table of ContentsTable of Contents, cont’dPowering the Display Device On and Off ...

Strona 60

Operation, cont’dMLC 52 Series MediaLink Controllers • Operation3-12Wiring and connections for the MLC 52 VC modelsConnect the cables to the MLC 52 IR

Strona 61 - Chapter Five

3-13MLC 52 Series MediaLink Controllers • OperationPowering offTo turn the projector/display off, press the Off button. The button blinks for4 secon

Strona 62 - Serial Communication

Operation, cont’dMLC 52 Series MediaLink Controllers • Operation3-14Using the IR Link with theMLC 52 and the IR 452• If an input selection button is i

Strona 63 - Installing the software

3-15MLC 52 Series MediaLink Controllers • Operation• The MLC recognizes the command it receives via the IR IN pole, andresponds as if its own equivale

Strona 64

Operation, cont’dMLC 52 Series MediaLink Controllers • Operation3-16ResettingIn the event that the MLC 52 needs to be reset, you can do so by one of t

Strona 65 - Loading Extron drivers

MLC 52 Series4Chapter FourSpecial ApplicationsApplication 1: Using Multiple Sources with an MLC 52Application 2: Controlling Projectors that Require P

Strona 66

MLC 52 Series MediaLink Controllers • Special Applications4-2Special ApplicationsThis chapter describes some special types of applications that repres

Strona 67

4-3MLC 52 Series MediaLink Controllers • Special ApplicationsProgramming buttons for an IR controlled system1 2 3 4 5 6 7 8 0 9 VIDEO S-Video RGB

Strona 68

Special Applications, cont’dMLC 52 Series MediaLink Controllers • Special Applications4-4If you are using an MLC 52 IR or an MLC 52 RS (one-gang model

Strona 69 - Key to file names

4-5MLC 52 Series MediaLink Controllers • Special ApplicationsIf you are using an MLC 52 IR VC or an MLC 52 RS VC (two-gang models) with atype A remote

Strona 70

iiiMLC 52 Series MediaLink Controllers • Table of ContentsOverview of the configuration procedure ...

Strona 71

Special Applications, cont’dMLC 52 Series MediaLink Controllers • Special Applications4-6Projector remote control type B (application 1)This remote co

Strona 72

4-7MLC 52 Series MediaLink Controllers • Special ApplicationsProgramming buttons for multiple inputs on an RS-232controlled systemIf the MLC 52 RS is

Strona 73

Special Applications, cont’dMLC 52 Series MediaLink Controllers • Special Applications4-8Configuring the MLC 52 for a power-off confirmationThe MLC 52

Strona 74

4-9MLC 52 Series MediaLink Controllers • Special ApplicationsApplication 3: Controlling Projectors That HaveMulti-coded IR FunctionalityCertain proje

Strona 75

Special Applications, cont’dMLC 52 Series MediaLink Controllers • Special Applications4-10b. Within 5 seconds (while the PC button on the MLC 52 is bl

Strona 76

4-11MLC 52 Series MediaLink Controllers • Special Applicationsb. Within 5 seconds (while the Video or blank button on the MLC 52 isblinking), press th

Strona 77

Special Applications, cont’dMLC 52 Series MediaLink Controllers • Special Applications4-12Issuing input selection commands learned from a type A remot

Strona 78

4-13MLC 52 Series MediaLink Controllers • Special ApplicationsProjector remote control type B (application 3)This remote control has only two input bu

Strona 79

Special Applications, cont’dMLC 52 Series MediaLink Controllers • Special Applications4-14Programming video inputs — projector remote control type B1.

Strona 80

4-15MLC 52 Series MediaLink Controllers • Special ApplicationsIssuing input selection commands learned from remote control type BThe MLC now has two c

Strona 81

iv MLC 52 Series MediaLink Controllers • Table of ContentsTable of Contents, cont’d68-1079-01 Rev. D04 07All trademarks mentioned in this manual are t

Strona 82

Special Applications, cont’dMLC 52 Series MediaLink Controllers • Special Applications4-16

Strona 83 - Displaying the Help program

MLC 52 Series5Chapter FiveSerial CommunicationUsing the MLC 52 Configuration ProgramUsing Simple Instruction Set (SIS™) Commands

Strona 84

MLC 52 Series MediaLink Controllers • Serial Communication5-2Serial CommunicationThe MLC 52 can be remotely configured via a host computer connected t

Strona 85

5-3MLC 52 Series MediaLink Controllers • Serial CommunicationInstalling the softwareTo install the MLC 52 configuration software on your computer,1. I

Strona 86

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-4By default the installation creates a directory called “Media

Strona 87

5-5MLC 52 Series MediaLink Controllers • Serial CommunicationLoading Extron driversExtron drivers are control files (libraries) of Extron-created proj

Strona 88

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-63. On the Drivers screen, select MLC 52/DVCM 50 Device Driver

Strona 89

5-7MLC 52 Series MediaLink Controllers • Serial CommunicationIR driver package list5. Click Run on the next two download screens that appear, to start

Strona 90

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-8IR driver information in the Help > Details windowChanging

Strona 91

5-9MLC 52 Series MediaLink Controllers • Serial CommunicationBrowse For Folder window5. Click OK on the IR Driver Directory.Key to file namesFile name

Strona 92

MLC 52 Series1Chapter OneIntroductionAbout the MLC 52 SeriesFeatures and OptionsMLC 52 Application Examples

Strona 93

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-10To configure the MLC using the Configuration Wizard,1. On th

Strona 94

5-11MLC 52 Series MediaLink Controllers • Serial Communication3. On the Select Initial Option screen, select the radio button for the type ofconnectio

Strona 95

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-12 Select COM Port screen3. The Detect Device Type screen a

Strona 96

5-13MLC 52 Series MediaLink Controllers • Serial Communication• For MLC 52 IR and MLC 52 IR VC:Select IR Driver screen for IR modelsOn the driver sele

Strona 97

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-14d. Click the Add Driver button. The selected manufacturer a

Strona 98

5-15MLC 52 Series MediaLink Controllers • Serial CommunicationAssign Commands To Buttons window with PC button selectedTo add a command to a button,a.

Strona 99

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-166. When finished programming buttons, click Next. The Uploa

Strona 100 - Serial Communication, cont’d

5-17MLC 52 Series MediaLink Controllers • Serial CommunicationWhen you click Finish with this option selected, a prompt appears,reminding you to save

Strona 101 - Projector Remote

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-18By default, the configuration files are stored at the follow

Strona 102

5-19MLC 52 Series MediaLink Controllers • Serial CommunicationWizard Finish screen10. On the Finish screen, select either of the radio buttons, then c

Strona 103 - Using emulation mode

MLC 52 Series MediaLink Controllers • Introduction1-2IntroductionAbout the MLC 52 SeriesThe Extron MediaLink™ Controller 52 (MLC 52) Series provide RS

Strona 104

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-20This section discusses configuring an MLC that is connected

Strona 105

5-21MLC 52 Series MediaLink Controllers • Serial CommunicationIf you want to create a configuration for an MLC that is not connected toyour computer,

Strona 106

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-22After a few seconds, the Extron MLC 52 Configuration Program

Strona 107 - Resetting

5-23MLC 52 Series MediaLink Controllers • Serial CommunicationDisplaying the Help programFor information on program features, do one of thefollowing t

Strona 108

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-24 Save configuration to... window.5. Click Save. Th

Strona 109 - Updating the firmware

5-25MLC 52 Series MediaLink Controllers • Serial CommunicationLoad configuration from... window3. If necessary, browse to locate the configuration fil

Strona 110

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-26Main screen with a driver addedThe main screen consists of t

Strona 111 - ) Commands

5-27MLC 52 Series MediaLink Controllers • Serial Communication Change IR Driver Location — Lets you select a folder where the MLCwill look for the IR

Strona 112

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-28 Details... — Displays the Details window, which gives deta

Strona 113 - Upload firmware

5-29MLC 52 Series MediaLink Controllers • Serial CommunicationButton Settings areaIn this section of the screen, you can enter text to label the MLC s

Strona 114

1-3MLC 52 Series MediaLink Controllers • IntroductionFront panel configuration port — This RS-232 serial port enables advancedconfiguration, driver do

Strona 115 - Appendix A

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-30Adding a driverTo add a serial (RS-232) or IR driver to the

Strona 116 - Specifications

5-31MLC 52 Series MediaLink Controllers • Serial Communication Select a serial driver... windowDouble-click on the driver for the desired device. Th

Strona 117 - Part Numbers and Accessories

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-32c. Click Yes if you want the configuration program to fill t

Strona 118 - Optional accessories

5-33MLC 52 Series MediaLink Controllers • Serial CommunicationPC button selected on MLC 52 main screen2. On the Driver tab in the Button Operations fi

Strona 119 - Appendix B

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-345. If you want to assign another command to the same button,

Strona 120 - (7.40 cm)

5-35MLC 52 Series MediaLink Controllers • Serial CommunicationUser-defined command entered for Video buttonIf you do not want to assign the command to

Strona 121 - MLC 52 VC

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-36 Volume mode (green): This mode is available only on the s

Strona 122 - Templates, cont’d

5-37MLC 52 Series MediaLink Controllers • Serial CommunicationFactory defaultsWhen your MLC 52 is delivered from the factory, or after a reset, the bu

Strona 123 - Extron’s Warranty

Serial Communication, cont’dMLC 52 Series MediaLink Controllers • Serial Communication5-38The Volume knob cannot be configured using the configuration

Strona 124

5-39MLC 52 Series MediaLink Controllers • Serial Communication• Automatically shut off projector power after being inactive for:Click the up and down

Komentarze do niniejszej Instrukcji

Brak uwag