HSA 400/402 Series • Reference Information
HSA 400/402 Series • Reference Information
Reference Information, cont’d
A-9
C = 9.613 0.0325"
(24.42 0.083 cm)
Cut surface material
out along this line.
Cut-Out Radius:
0.25" (0.6 cm)
Tilting Plate Top Panel
Cut-Out Template for Extron's HSA 400
TEMPLATE IS NOT FULL SIZE.
User Access (Connectors and AAP Openings)
International Model
G
H
4.475" (11.37 cm)
6.425" (16.32 cm)
10.113"
(25.74 cm)
8.163"
(21.88 cm)
D = 5.925 0.0325"
(15.05 0.083 cm)
+
+
+
+
SURFACE CUT-OUT
AREA = 9.613 0.0325"
(24.42 0.083 cm) x
5.925 0.0325"
(15.05 0.083 cm)
+
+
+
+
Figure A-6 — HSA 400 International cut-out template
A-8
Cut surface material
out along this line.
Tilting Plate Top Panel
Cut-Out Template for Extron's HSA 402
TEMPLATE IS NOT FULL SIZE.
Cut-Out Radius:
0.25" (0.6 cm)
C = 10.344 0.0325"
(26.27 0.083 cm)
User Access (Connectors and AAP Openings)
US Model
4.475" (11.37 cm)
6.425" (16.32 cm)
10.844"
(27.54 cm)
8.894"
(22.59 cm)
D = 5.925 0.0325"
(15.05 0.083 cm)
+
+
+
+
SURFACE CUT-OUT
AREA = 10.344 0.0325"
(26.27 0.083 cm) x
5.925 0.0325"
(15.05 0.083 cm)
+
+
+
+
H
G
Figure A-5 — HSA 402 US/domestic cut-out template