68-2117-01 Rev. A12 11TLP 710CVUser GuideTouchLink™7" Cable Cubby® TouchLink™ Touchpanel
Installation OverviewThis section provides an overview of the main steps required to install the TLP 710CV and provides links to more detailed explana
MountingThis section provides detailed instructions for mounting the TLP 710CV in a table and installing the AAPs. It covers: z Planning z Tools Requi
Tools Required for InstallationThe following tools are required but not supplied:Safety GlassesPhillips Screw DriverTape Measure1/4" Hex Nut Driv
Cutting the TableCutout DimensionsCAUTIONS: • The table should be cut only by licensed and bonded craftspeople. • Make certain the correct cutout
Running CablesRun all cables necessary to support the AC connector, the cables stored in the cubby, and all planned AAP connectors. Run the cables bel
2. Run the cable or conduit to a convenient junction box. Extron recommends the circuit be attached to a junction box that is directly wired to the m
3. Attach the AAP loosely to the bracket with the supplied #4-40 captive washer nuts.NOTE: At this time, captive washer nuts should be hand tightene
4. Use a hex nut wrench to tighten the AAP captive washer nuts. NOTE: When the AAP assembly was initially prepared, the nuts were hand tightened (se
Touchpanel Features and ConnectorsThis section discusses the features and connectors of the TLP 710CV touchpanel.Front PanelWith the lid down, the lig
acbgfedFigure 7. TLP 710CV Front Panel with Bezel Removeda Light Sensor — mounted on top of the screen. The sensor monitors the level of ambient lig
This symbol is intended to alert the user of important operating and maintenance (servicing) instructions in the literature provided with the equipmen
TLP 710CV ConnectorsThe rear panel of the TLP 710CV has a compartment that can be accessed from beneath the unit. This compartment contains the connec
Network and Power over Ethernet ConnectorThe TLP 710CV connects to a network using a twisted pair cable, terminated with an RJ-45 connector. Use a str
Power ConnectorConnect the two pole, 3.5 mm captive screw connector from the 12 VDC, 1.0 A power supply (not provided) to the power supply socket on t
Configuration and Calibration OverviewBy now, the TLP 710CV must be installed in a suitable place, all necessary cables securely attached, and the unit
Initial Configuration and CalibrationThis section describes: z How to Access the Internal On-screen Menus z The Main, Volume, Time, Network, and Video
The screen may need a high level of backlighting for readability when ambient lighting is high. With low ambient lighting, the backlighting should be
Time ScreenExitDown UpMonth: 06Down UpHours: 13Down UpDay: 06Down UpMinutes: 32Down UpYear: 2011MainVolumeTimeNetworkVideoFigure 13. Time ScreenUse t
Video ScreenExitMainVolumeTimeNetworkVideoDown UpContrast: 064Down UpColor: 064Down UpBrightness: 128Down UpTint: 128Figure 15. Video ScreenWhen a vi
Configuration SoftwareThis section of the user guide provides information about: z The Configuration Software z Installing the Software z Using the Touc
If required, locate the Global Congurator program on the disc or website and install that also. By default, the Installer program creates and places
FCC Class A NoticeThis equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rule
2. Click the Configuration tab and select System Settings, which allows the user to modify the IP settings and the date and time settings. These corr
5. Click the Touchpanel tab, which allows the user to alter the touchpanel and volume settings. These correspond to the Main settings (see page 18) a
3. From the same site, download the firmware for the TouchLink touchpanel. Click the Download tab on the Extron home page and select the Firmware opti
Updating Firmware From a Web Browser1. Power on a computer that is connected to the same network as the TLP 710CV.2. From the Extron website (www.ex
Using GUI ConguratorThis section provides an overview of the GUI Congurator program. For complete information about the program, consult the GUI Con
2. You can choose to: z Start a New Project — Clicking OK opens a dialog box that offers a choice of project options.Figure 26. GUI Configurator New
If you are working on the project, leave the Open as read-only box unchecked.Click Open to open the le. The project opens in GUI Congurator. z Downl
3. Depending on which option was selected in step 2, GUI Congurator opens to a new or existing project. The initial screen is divided into a series
5. The project can be uploaded to one or more TouchLink touchpanels. To add a touchpanel:a. From the Project menu, select Add > Panel:Figure 30.
If this project has been uploaded to the TouchLink touchpanel before, you can choose to upload the changes that have been made to the previous version
Conventions Used in this GuideIn this user guide, the following are used:CAUTION: A caution indicates a potential hazard to equipment or data.NOTE:
2. Select Create A New Project and click OK. The dialog box closes, leaving the Project Settings screen.Figure 33. Global Configurator Project Settin
4. Click OK. The Project Settings screen closes and is replaced by the Add Device dialog box:Figure 34. Global Configurator Add Device Dialog BoxTo s
5. Click OK. The Add Device screen closes. The start-up screen, which was behind it, is now visible, showing the IP Link control processor and the av
The Add TouchPanel dialog box opens.Figure 37. Add TouchPanel Dialog Boxa. Ensure the TouchLink touchpanel model is selected from the drop-down menu
Specications DisplayScreen type ... Active matrix TFT color displaySize ...
Audio input — see S-video or composite video MTP transmitters or TLP VIM specicationsNumber/signal type ... 1 stereo, balanc
Dimensions diagram examples9.55"(242.6 mm)9.85"(250.1 mm)7.75"(196.9 mm)4.08"(103.7 mm)7.40"(187.9 mm)8.84"(224.5 mm)7.0
Product weight ... 5.8 lbs (2.6 kg)Shipping weight ... 11 lbs (5 kg)Vibration ...
Accessories and Part NumbersIncluded PartsDescriptionPart NumberTLP 710CV TouchLink touchpanel 60-1175-02xxPower over Ethernet power inserterCable cub
Reset ModesThe TLP 710CV has four reset modes that correspond to four of the five reset modes for the IP Link controllers. The modes are initiated by
ContentsIntroduction ... 1About This Guide ... 1About the TLP 710CV
Extron Headquarters+1.800.633.9876 (Inside USA/Canada Only)Extron USA - West Extron USA - East +1.714.491.1500 +1.919.863.1794 +1.714.491.1517 FAX +
TLP 710CV • Contents vi
Introduction z About This Guide z About the TLP 710CV z Features z RequirementsAbout This GuideThis guide describes the function, installation, congu
Light sensor — allows the auto dimming feature to adjust LCD screen backlighting to take account of ambient lighting.Lid switch — when the lid is op
RequirementsHardware and SoftwareThe latest system requirements for running the configuration software can be found on the Extron website: z GUI Configu