Extron electronics MTPX Plus Series Instrukcja Konfiguracji Strona 22

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 28
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 21
Refer also to the MTPX Plus User’s Manual at www.extron.com.
Command ASCII command
(host to switcher)
Response
(switcher to host)
Additional description
IP setup
Set IP address
EX2^
CI
}
Ipi
X2^]
Read IP address
E
CI
} X2^]
Set subnet mask
EX2^
CS
}
Ips
X2^]
Read subnet mask
E
CS
} X2^]
Set gateway IP address
EX2^
CG
}
Ipg
X2^]
Read gateway IP address
E
CG
} X2^]
Set DHCP on or off
EX2&
DH
}
Idh
X2&]
Read DHCP on/off status
E
DH
} X2&]
Set verbose mode
EX2*
CV
}
Vrb
X2*]
Read verbose mode
E
CV
} X2*]
Configure current port timeout
E
0*
X2(
TC
}
Pti0*
X2(]
Read current port timeout
E
0TC
} X2(]
Configure global IP port timeout
E
1*
X2(
TC
}
Pti1*
X2(]
Read global IP port timeout
E
1TC
} X2(]
N
X2^
= IP address ###.###.###.###
X2&
= DHCP 0 =1 off, 1 = on
X2*
= Verbose mode 0 = clear/none (default for Telnet connection)
1 = verbose mode (default for RS-232/RS-422 connection)
2 = tagged responses for queries
3 = verbose mode and tagged for queries
X2(
= Port timeout interval 1 (= 10 seconds) - 65000 (default is 30 = 300 seconds = 5 minutes)
MTPX Plus • Remote Control and Optimizing the Video
Remote Control and Optimizing the Video, cont’d
4-14
Przeglądanie stron 21
1 2 ... 17 18 19 20 21 22 23 24 25 26 27 28

Komentarze do niniejszej Instrukcji

Brak uwag