Resetting the SME100 Using the Rear Panel
The Reset button on the rear panel of the SME100 is used to reset the SME100. To select
different reset levels, use a pointed stylus or small screwdriver to press and hold the Reset
button while the SME100 is running or press and hold the Reset button while applying
power to the SME100.
ATTENTION: Review the reset modes carefully. Using the wrong reset mode may
delete important information and configuration settings. The table on the next page
provides a summary of the reset modes.
NOTES:
The reset modes listed in the table on the next page close all open IP and Telnet
connections and all sockets.
Each reset mode is a separate reset (not a continuation from mode 1 to
mode 5).
Reset mode 2 and 3 are not available for the SME100.
For information on resetting the SME100 using the web-based user interface, see
the "Reset Page" section on page 116.
For information on resetting the SME100 using front panel menu system, see the
"Advanced Config Menu" section on page 36.
For information on resetting the SME100 using SIS commands, see
"Resets / Reboot" on page 152 of the "Command and Response Table for SIS
Commands" section.
RESET
RESET
RESET RESET
RESET
Release, then immediately
press and release again. Reset
LED flashes in confirmation.
Modes 4 and 5
Press and hold
the Reset button.
Mode 1
Reset LED flashes
twice or three times.
Press and hold for
6 or 9 seconds.
Apply power
to the SME 100.
Release Reset button.
Figure 11. Resetting the SME100